Laboratory of Ion Beam Applications (IBA Lab)
Most of the experimental facilites of our laboratory are based on a 5 MV Van de Graaff (VdG) electrostatic accelerator. VdG provides energetic ions (H+, D+, He+, etc.) for ion beam analysis, physical experiments, as well as for the modification and testing of materials.

Beamlines used for ion beam applications:
- Experimental setups
- Macro-PIXE chamber (L45o)
- Macro-PIGE, DIGE, NRA chamber & in-air PIXE (R30o)
- Oxford Microbeams-type scanning nuclear microprobe (0o)
- XRF (X-ray Fluorescence) setup
- Accessories
- Detectors:
- Si(Li)
- SUTW Si(Li)
- Ge(Li)
- Clover-Ge-BGO
- PIPS
- PIN
- Electronics:
- power supplies
- preamplifiers
- amplifiers
- digital signal processors
- ADCs
- MCAs
- AIM
- Data Acquisition Systems
- current integrators
- Analytical software:
- Gamma: FGM (Comp. Phys. Comm. 34 (1985) 313)
- PIXE: PIXEKLM-TPI (NIMB 231 (2005) 156)
- RBS: RBX (NIMB 85 (1994) 588); WINDF (NIMB 136 (1998) 1157)
- XRF: AXIL (IAEA)
- Laboratory for sample preaparation
The research infrastructure of the laboratory was upgraded in the framework of the EU co-funded Economic Competitiveness Operative Programme (GVOP-3.2.1.-2004-04-0402/3.0) in 2006, including oil-free vacuum system, vacuum coating system, nuclear electronics, X-ray detectors, optical microscope and a quadrupole magnet lens.
Macro-PIXE chamber
Macro-PIXE (broad beam) chamber for analytical and radiation chemistry studies.
|
![]() |
Macro-PIGE, DIGE, NRA chamber & in-air PIXE
Broad beam chamber & external-beam setup for analytical measurements and physical studies
|
![]() |
Oxford Microbeams type scanning nuclear microprobe facility
Features:
- Oxford-type quadruple triplet
- Beam spot size: 1.5 x 1.5 µm2 (20 pA); 0.6 x 0.7 µm2 (<1 pA)
- Max mapping (scan) size: 2.5 x 2.5 mm2
- X-Y-Z translator and two axes goniometer
- Microscope & camera
- Oil free vacuum system
- Beam chopper
- Micro-IBA (PIXE, PIGE, DIGE, NRA, RBS, ERDA, STIM), IBIC (DL>1 ppm)
- Analyzable elements:
- H (ERDA)
- Li..Si (NRA/DIGE/PIGE)
- B..U (PIXE and RBS)
- Depth resolution: 2-20 nm
- vacuumable, solid samples (<50 mm):
e.g. archaeological, atmospheric aerosols, biological, geological, industrial, etc.

XRF (X-ray Fluorescence) setup
Analyzable elements: Na-U (DL=100-0.5 ppm) |
Zeiss Axio Imager Optical Microscope
Features:
|
|
Leybold UNIVEX 350 Vacuum Coating System
The evaporator provides the possibility of thermal and electron beam evaporation. The system is equipped with computer controlled vacuum system, programmable electron beam sweeper, film thickness monitor, automatic source shutters and rotatable substrate holder. |
![]() |
Cole-Parmer Ultrasonic cleaner & thermostat
model 08895-22, 100W |
|
Cammax Precima Spincoater
800-8000 rpm |
|
Arex Heating Magnetic Stirrer (Velp Scientific)
|